Swimming Pool Air Source Heat Pump

Feedback Form

General features
1. Swimming pool air source heat pump has automatic operation mode
2. It features auto-restart and auto defrosting.
3. The heat pump has friendly and intelligent LCD Control panel interface.
4. Both cooling & heating mode are optional for this heat pump.
5. The product presents wide working ambient temperature, ranging from 10 ºC to 43ºC.
6. It adopts world famous Copeland compressor.
7. Finally it includes Green refrigerant R410a/R407c for environment safety etc.

Advantages of Swimming pool air source heat pump
1. The heating capacity ranges from 7kW, 220V/1ph/50Hz to 230kW, 380V/3ph/50Hz
2. The swimming pool air source heat pump has long operating life by using the advanced stainless steel/titanium heat exchanger, which resists the erosion from chlorine in the water and creates a longer life span.
3. It is designed for comprehensive anti-corrosion feature, in which the special case design adopts stainless steel bolts and nuts. The holes for bolts are designed to avoid the damage of the coating. Durable coating in white or stainless steel is available
4. Special design for the fan shroud, with accurate and equal distance between the fan blades and fan shroud, offers low vibration, and low noise when running.
5. The heat pump features intelligent defrosting with revert circuit.
6. This product has cover on remote wire control panel and is waterproof
7. The refrigerant available for our swimming pool air source heat pump is R22/ R407C/ R410A.
8. Our heat pump is remarkably compact with flow switch built inside.
9. Our swimming pool air source heat pump offers safety for both water and electricity by separating insulated part without electric shock.
10. The whole units of the product are warranted for one year period.

Technical Specification of Swimming Pool Heat and Chill Pumps - Vertical style

Model Units HLRD
9-YC
HLRD
15-YC
HLRD
24-YC
HLRD
30-YC
HLRD
36-YC
HLRD
45-YC
HLRD
60-YC
HLRD
75-YC
HLRD
95-YC
HLRD
125-YC
HLRD
150-YC
Heating Capacity kW 13.5 21.3 35.5 45.5 52.8 66 87.4 110 140 191 230
BTU/h 46000 73000 121000 155000 180000 225000 300000 376000 480000 650000 785000
COP ---- 4.33 4.96 4.87 4.84 4.74 4.46 4.65 4.73 4.87 5.08 4.94
Cooling Capacity kW 8.8 14.7 25.5 30.5 35.8 44.9 59.5 75 95.2 126.9 150
BTU/h 30000 50000 87000 104000 122000 153000 203000 256000 325000 430000 512000
EER ---- 2.67 2.68 3.00 2.78 3.12 2.78 2.71 2.80 3.20 2.89 2.79
Max Water Outlet Temperature 45
Power Supply V/PH/HZ 220-240V/1N~/50Hz 380V-400V/3N~ /50Hz
Rated Input Power (Heating/Cooling) kW 3.12/
3.30
4.3/
5.50
7.30/
8.50
9.4/
11.00
11.15/
11.50
14.80/
16.20
18.80/
22.00
23.30/
26.80
28.80/
29.80
37.60/
44.00
46.60/
53.80
Rated Input Current (Heating/ Cooling) A 14.5/
15.3
6.5/
9.9
11/
13.4
14.2/
19.8
20.1/
19.24
28.2/
30.1
33.9/
39.7
42.0/
48.3
51.92/
53.7
67.8/
79.4
84.00/
96.6
Max Input Power kW 3.4 6.1 10 13.5 15.1 18.9 25.4 31.5 38.75 50.8 63
Max Input Current A 15.5 9.2 15.2 20.6 27.2 34.1 45.8 56.8 69.86 91.6 113.6
Ambient Temperature -10℃~43℃
Heat Exchanger   Titanium in seamless stainless steel
Refrigerant/Chare Qty kg R407C
/1.5
R407C
/1.9
R407C
/1.7*2
R407C
/3.8
R407C
/2.2*2
R407C
/3.5*2
R407C
/4.5*2
R407C
/5.5*2
R407C
/6.5*2
   
Compressor Type   Scroll
Number of Compressors   1 1 2 2 2 2 2 2 2 4 4
Number of Fans   1 1 2 2 2 2 2 2 2 4 4
Fan Air Flow Volume m3/h 3900 6500 13000 13000 15600 19500 26000 32500 39000 65600 78000
Fan Direction   Vertical
Fan Power Input W 180 260 320×2 320×2 550×2 550×2 640x2 1100x2 1100x2 640x4 1100x4
Fan Rotation Speed RPM 850 850 790 790 820 820 790 820 820 790 820
Noise dB (A) ≤54 ≤56 ≤61 ≤61 ≤66 ≤66 ≤66 ≤68 68 71 72
Piping Diameter mm DN40 DN40 DN50 DN50 DN50 DN65 DN65 DN80 DN80 DN80 DN100
Discharge Pressure Mpa 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5    
Suction Pressure Mpa 0.3-0.8 0.3-0.8 0.3-0.8 0.3-0.8 0.3-0.8 0.3-0.8 0.3-0.8 0.3-0.8 0.3-0.8    
Rated Water Pressure Mpa 0.2~0.6
Max Water-in Pressure Mpa 1 1 1 1 1 1 1 1 1    
Min Water-in Pressure Mpa / / / / / / / / /    
Water Flow Volume m3/h 2.52 3.77 6.00 7.54 9.05 11.31 14.98 18.86 24.00 32.74 39.43
Net Weight kg 90 114 214 244 276 450 472 680 720 944 1360
Shipping Weight kg 102 128 238 268 316 487 526 734 785 1052 1468
Product Dimension mm 695
/655
/740
703
/687
/930
1450
/705
/965
1450
/705
/1065
1450
/710
/1255
1580
/850
/1570
1990
/980
/2050
1990
/980
/2050
1900
/1020
/2050
2015
/2200
/2025
2015
/2200
/2025
Shipping Size mm 787
/775
/842
816
/797
/1045
1535
/835
/1083
1535
/835
/1184
1560
/830
/1355
1700
/970
/1670
2110
/1100
/2150
2110
/1100
/2150
2120
/1140
/2150
2115
/2300
/2075
2115
/2300
/2075
Certificates   CE/CB/C-TICK/SAA CE    
Notes:
1. Heating working condition: Outdoor DB/WB temp: 24℃/19℃,62.5%RH, inlet/outlet water temp:27℃/32℃.
2. Cooling working condition: Outdoor DB/WB temp: 43℃/37℃,68%RH, inlet/outlet water temp:32℃/27℃.
3. Other sizes are available. 4. COP = heating capacity / heating power input (for heating).
5. EER = cooling capacity / cooling power input (for cooling).
6. Sizing: P= (CV (T2-T1)/t)*1.20 where P=Capacity required (kW), C=Coefficient (1.163), V=Water volume (m³), T2=Target water temp (°C), T1=Water temp before heating (°C), t=time to heat, plus add 20%.

Technical specification of Swimming Pool Heat and Chill Pumps- Horizontal style

Model Units HLRC5-YC HLRC8-YC HLRC9-YC HLRC15-YC
Heating Capacity kW 7 9.8 13.5 21.3
BTU/h 24000 33400 46000 73000
COP ---- 4.83 4.76 4.33 4.96
Cooling Capacity kW 4.5 6.2 8.8 14.7
BTU/h 15000 21000 30000 50000
EER ---- 2.73 2.82 2.67 2.68
Max Water Outlet Temperature 45
Power Supply V/ph/Hz 220-240V/1N~/50Hz 380V-400V/3N~/50Hz
Rated Input Power (Heating/Cooling) kW 1.45/1.65 2.06/2.20 3.12/3.30 4.3/5.50
Rated Input Current (Heating/ Cooling) A 6.6/7.5 9.6/10.2 14.5/15.3 6.5/9.9
Max Input Power kW 1.9 2.5 3.4 6.1
Max Input Current A 9.1 11.5 15.5 9.2
Ambient Temperature -10℃~43℃
Heat Exchanger   Titanium in seamless stainless steel
Refrigerant/Charge Qty kg R407C/1.1 R407C/1.1 R407C/1.5 R407C/1.9
Compressor Type   Rotary Scroll
Number of Compressors   1 1 1 1
Number of Fans   1 1 1 2
Fan Air Flow Volume m3/h 2000 2600 3900 6500
Fan Direction   Horizontal
Fan Power Input W 90 120 180 130x2
Fan Rotation Speed RPM 850 850 850 850
Noise dB (A) ≤48 ≤50 ≤54 ≤56
Piping Diameter mm DN25 DN25 DN40 DN40
Discharge Pressure Mpa 2.5 2.5 2.5 2.5
Suction Pressure Mpa 0.3-0.8 0.3-0.8 0.3-0.8 0.3-0.8
Rated Water Pressure MPa 0.2~0.6
Max Water-in Pressure Mpa 1 1 1 1
Min Water-in Pressure Mpa / / / /
Water Flow Volume m3/h 1.20 1.68 2.31 3.65
Net Weight Kg 38 67 97.5 114
Shipping Weight Kg 51 85 113.5 128
Product Dimension mm 1150/350/620 1150/350/620 1115/425/710 1110/420/1222
Shipping Dimension mm 1200/400/670 1200/400/670 1242/540/782 1220/530/1337
Certificates   CE CE/CB/C-TICK/SAA
Notes:          
1. Heating working condition: Outdoor DB/WB temp: 24℃/19℃, 62.5%RH, inlet/outlet water temp:27℃/32℃.
2. Cooling working condition: Outdoor DB/WB temp: 43℃/37℃, 68%RH, inlet/outlet water temp: 32℃/27℃.
3. Other sizes are available.
4. COP = heating capacity / heating power input (for heating).
5. EER = cooling capacity / cooling power input (for cooling).
6. Sizing: P= (CV (T2-T1)/t)*1.20 where P=Capacity required (kW), C=Coefficient (1.163), V=Water volume (m³), T2=Target water temp (°C), T1=Water temp before heating (°C), t=time to heat, plus add 20%.

The swimming pool air source heat pump can be installed in many environments, including a constant temperature swimming pool, sauna constant hot water system, or for application of supplying hot water at home.

We is a swimming pool air source heat pump manufacturer in China. Our company provides a wide range of products including DC inverter air source heat pump, household heat pump water heater, and tube solar water heater, among others.

Inquiry Form
Other Products
  • DC Inverter Air Source Heat Pump With the advanced DC inverter technology, We DC inverter air source heat pump can save 65% heating cost, compared to the traditional heating device like gas/fuel boiler...